Additional
information CAN (Controller Area Network) is a serial bus system especially
suited to structure intelligent industry devices networks and build smart automatic
control systems. The following figure shows the application architecture for I-7530A
modules. The PC can be the CAN host, monitor or HMI to access/control the CAN device
through the CAN network by the I-7530A Converter.
The programmable RS-232/485/422
device (For example: I-8411/I-8431/I-8811/I-8831/W-8031/W-8331/W-8731 embedded controller)
can use the serial port to connect to the CAN network via the I-7530A module. In
order to use the CAN network with traditional RS-232/485/422 devices, we provide
a way to achieve this purpose. The I-7530A is designed to unleash the power of CAN
bus via RS-232/485/422 communication method. It accurately converts messages between
CAN and RS-232/485/422 networks. This module let you to communicate with CAN devices
easily from any PC or devices with RS-232/485/422 interface. 
Moreover, we expand the functionalities of I-7530A for some special application.
In pair connection mode, I-7530A can be used to connect PC with other RS-232/485/422
devices at the same time. The application architecture may be as follows.  3000V isolation on CAN side
The CAN port of I-7530A is an isolated with 3000V isolation. This isolation can
protect the local RS-232/485/422 devices from the damage signal coming from CAN
network.
Watchdog inside
The I-7530A Watchdog is a hardware reset circuit to monitor the I-7530A’s operation
status. When working in harsh or noisy environment, the I-7530A may be down by the
external signal. The circuit may let the I-7530A to work continuously and never
halt.
Power and Error indicator display
There are two indicators on the I-7530A.The power indicator can help user to check
whether the I-7530A is standby or transmitting/receiving messages. The Error indicator
will be turned on when some errors occur on the I-7530A.
Features - Compatible with CAN specification 2.0A and B
- Fully compatible with ISO 11898-2 standard
- Support various bauds from 10K bps to 1M bps
- Jumper for 120 Ω terminator resistor
- Software configurable CAN and RS-232 /422/485 communication parameters
- Power, data flow and error indicator for CAN and RS-232/422/485
- Watchdog inside
- Provide the transparent communication between the RS-232/485/422 devices via CAN bus
- Enable different RS-232/485/422 devices into an individual group in CAN bus network.
(Full-duplex communication mode of RS-232/422 devices is not supported) Software Utility Features - CAN bus Baud rate configuration
- CAN acceptance filter configuration
- CAN 2.0A or 2.0B specific selection
- RS-232/485/422 Baud rate and data bit setting
- RS-232/485/422 responded selection
- Easy test to transmit/receive CAN messages
- Setting for I-7530A communication mode (normal mode or pair connection mode)
CAN Monitor & Datalog Tool - t has a CAN message field which can display the receiving CAN messages in Decimal or HEX mode.
- Can display the timestamp of each received CAN message.
- Users can change the display mode, up-down, down-up or stop.
- It can count the number of received CAN messages.
- Data Log : It can save the CAN message as “ txt ” file.
- Has CAN ID filter function.
- Can send CAN message to CAN BUS according the defined interval time.

Technical parameters CAN Interface | Controller | Microprocessor inside with 20MHz | Transceiver | NXP 82C250 | Connector | 9-pin male D-Sub (CAN_L, CAN_SHLD, CAN_H, N/A for others) | Port Channels | 1 | Buad Rate | 10 k, 20 k, 50 k, 100 k, 125 k, 250 k, 500 k, 800 k and 1 Mbps | Protection | 3000 VDC power protection on CAN side, 2500Vrms photo-couple isolation on CAN bus | Terminator Resistor | Selectable 120Ω terminator resistor by jumper | Support Protocol | CAN 2.0A/2.0B | Receive Buffer | 1000 data frames | UART Interface | COM | RS-232、RS-485、RS-422 | Connector | 14-pin terminal connector
RS-232 : TxD, RxD, GND
RS-422 : Tx+, Tx-, Rx+, Rx-
RS-485 : D+, D- | Baud Rate | 110, 150, 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps | Data Bits | 5, 6, 7, 8 | Stop Bits | 1,2 | Parity | None, Even, Odd | Receive Buffer | 900 data frames | Power | Power Consumption | 1W | Power Requirement | Unregulated +10V DC ~ +30V DC. Power reverse protection, Over-Voltage brown-out protection | LED | Round LED | ON LED: Power and Data Flow; ERR LED: Error | Mechanism | Installation | DIN-Rail | Dimensions | 118mm x 72mm x 33mm | Environment | Operating Temp. | -25℃ to 75℃ | Storage Temp. | -40℃ to 80℃ | Humidity | 5~95% non-condensing | |