Software and manuals

GW-7552

PROFIBUS/Modbus Gateway
 
      Request for information        

Additional information

The GW-7552 Gateway is specially designed for the slave device of PROFIBUS DP protocol. It allows the PROFIBUS master to access the Modbus devices. These Modbus devices may be a PLC, a sensor, ICPDAS M-7000 series modules and so forth. In addition, we also provide the utility software for users to configure the GW-7552. By using this module, users can put their Modbus devices into PROFIBUS network very easily.



The GW-7552 Utility helps users to configure the devices, and has following features:
  • Provide GW-7552 safe value setting
  • Display module parameters of the GW-7552
  • Show module address configuration of the GW-7552

  • Technical parameters

    Specification:
    Protocol & Hierarchy
    DP-V0 Slave
    Supports PROFIBUS Transmission Rate (Kbps)
    9.6, 19.2, 45.45, 93.75, 187.5, 500, 1500, 3000, 6000, 12000
    Transmission Rate Setting
    detected automatically
    Max Input Data Length
    128 Bytes
    Max Output Data Length
    130 Bytes
    Address Setting
    0~126 set by DIP switch
    Supports Modbus Mode
    Master/Slave
    Supports Modbus Format
    RTU/ASCII
    Hybrid COM 1
    RS-232/422/485 with “Self Tuner” inside
    Supports COM 1 Baudrate (Kbps)
    2.4, 4.8, 9.6, 19.2, 38.4, 57.6, 115.2
    Supports COM 1 Data Format
    7/8 data bits, No/Odd/Even parity, 1/2 stop bit
    Indicators
    PWR, ERR, and RUN LEDs
    Network Isolation Protection
    High Speed iCoupler
    DC Isolation Protection
    3000VDC on PROFIBUS side
    Modbus Support
    Code
    Name
    Description
    01
    Read Coil Status
    Read the ON/OFF status of discrete outputs in the slave
    02
    Read Input Status
    Read the ON/OFF status of discrete inputs in the slave
    03
    Read Holding Registers
    Read the binary contents of holding registers in the slave
    04
    Read Input Registers
    Read the binary contents of input registers in the slave
    05
    Force Single Coil
    Write a single output to either ON or OFF in the slave
    06
    Preset Single Register
    Write an integer value into a single register in the slave
    15
    Force Multi. Coils
    Write each coil in the sequence of coils to either ON or OFF in the slave
    16
    Preset Multi. Registers
    Write a block of contiguous registers in the slave
    Hardware Specifications
    Model
    GW-7552
    CPU
    80186, 80MHz
    Flash
    512K Bytes
    SRAM
    512K Bytes
    EEPROM
    16K Bytes
    Watch Dog Timer
    CPU Built-in
    COM 1
    RS-232(3 wires)/RS-422/RS-485
    Baudrate
    Up to 115.2Kbps
    PROFIBUS Interface
    9-pin D-Sub(Female)
    PROFIBUS Controller
    Siemens SPC3
    PROFIBUS Transceiver
    ADI ADM2486 iCoupler Isolated Transceiver
    Transmission Rate
    Up to 12Mbps
    Power Requirement
    10V ~ 30V
    Power Consumption
    2.5W
    Operating Temp.
    -25℃ ~ +75℃
    Storage Temp.
    -30℃ ~ +85℃
    Humidity
    5% ~ 95%
    Dimensions